CRACKING 101 - 1990 edition
Lession #1
┌────────────────────┐
│ CRACKING DOS Files │
└────────────────────┘
By Buckaroo Banzai
Today I'm here to about is cracking a dos format (either .EXE or .COM)
file. This, in my mind is releativly the simplest (in theory although pratice
might say otherwise) type of crack to do.
There are really 3 steps in cracking a dos file. Step 1, is finding where
the protection routine is. How to go about it, well, there are several
diffrent methods. Here are the steps that I often use.
First, I will run the program under PC-WATCH (PW) trapping INT13 all
functions and INT21 functions 3Dh and 3Fh. Why trap the functions. This will
give (hopefully) a starting place to look for the protection. Once you have
set the breakpoints, press [F4] to execute and you will drop to dos. When you
do, PW should display several calls to INT13. What closly at the CS:IP of
these calls. Record it for later because these are calls from dos. We will
uses this data to recognize what is a call to the protection and what is not.
Next, run the program to be cracked. As it executes, PC-WATCH will show
what files are opened (including the file you just ran since DOS uses
function 3Dh to open a file when it executes one) and what (and more
improtantly WHERE) data is read to. Makes a list saying what data is read in
from what file. Here is an example. Lets say you ran the program "XXX.COM".
While running, "XXX.COM", you noticed that 2 other files "YYY.BIN" and
"ZZZ.BIN" were also opened. So make a list like this:
XXX.COM YYY.BIN ZZZ.BIN
─────── ─────── ───────
Now, lets say that after "XXX.COM" was opened, PW showed that there were
2 reads from "XXX.COM" (the way to tell where the data is being read from is
by checking the BX register on calls to 3Fh and the AX registers after calls
to 3Dh. Yes, you should select both INPUT REGISTERS and OUTPUT REGISTERS from
the PW menu) 1 at aaaa:bbbb and 1 as cccc:dddd. Right after "YYY.BIN" was
opened, PW showed data was read to eeee:ffff and then after "ZZZ.BIN" was
opened, data was written to gggg:hhhh and iiii:jjjj. Now, our list looks like
this:
XXX.COM YYY.BIN ZZZ.BIN
─────── ─────── ───────
aaaa:bbbb eeee:ffff gggg:hhhh
cccc:dddd iiii:jjjj
What we have just created in a program load map. This map shows where to
program to be cracked is loaded in memory. Next, scan though the calls to
INT13. Look for either calls that return with errors, calls that have high
values in the CH ( > 28) or CL ( > 9) registers, or calls not made by dos
(those calls that have a CS:IP diffrent from the one we copied down before we
executed the program). Now, look at the CS:IP of the call to INT13. Match the
segment address against the program load map. If only 1 match occurs, then
you now know what module the check is in so continue on to step #2. If more
than 1 match occurs, check the offset (IP). Find the one that is closest to
one of the write address's offset. Once you find a match, then go on to step
#2. If no match occurs after both steps, it's time to track through the
program.
Tracking your way though the program is a real bitch. I do not like to do
because it can just take to long. But here is an overview on how it is done.
The object, is to keep narowing down calls until disk access if found.
How to do this. Well, load the program under debug. Keep tracing through the
program in till a "CALL" instruction is found. Jot down you current IP and
PROCEED (using debug P command) over the instruction without tracing in to
it. If you end up at the next instruction without access that disk, then you
have not found the routine you are looking for so keep going. Search for the
next "CALL" and then the next and then the next etc. At some point, when you
proceed over a call, the disk will either check protection or load in a new
module.
How to tell the diffrence, well PW is still active and will tell you if
it was a call to INT13 or INT21 or BOTH. If it was the call to INT13 or a
call to BOTH then you have found a call to the protection routine (although
the actual call may be 100 levels deeper, you are on the right track). Exit
and restart but this time when you reach the call, trace into it. Now do the
same process until you get to the call to the next level, then again for the
next, etc. Finally you should find where it is.
But hopefully, you won't have to do that. As I said, it is very time
consumming. Hopefully, you will know which module to look in. If you do, here
is how to find the call to the protection. First, try the simple search
method. Load up the module using DEBUG and simply type:
S CS:100 FFFF CD 13 (use CS:100 if .EXE)
Debug will hopefully list 1 or more address. If not, try the same command
only using CS:0000. If again you are not givin any address, you have some
tricky debugging at hand (an I suggest rereading the exercise in self-
modifying code).
I will explain in detail how to find self-modifying code later but for
now, lets assume we have found the protection routine. Next, is to figure out
what the copy protection is trying to do. First, look to the printout from
PW. Look through it until you find the calls the INT13 from the protection
routine. Look at the AH register. If it is 00h then the protection routine is
probally reading in data from the protected tracks. If not, then the
protection is simply looking for some KEY (in other words a damaged track or
sector) that DOS cannot duplicate.
The second choice is much eaiser to defeat. 2 quick methods to defeating
this type. First, you can fake the call and simply set the registers. Take
the follow check to a protection routine:
1: mov AX,0201h ; Read 1 sectors using int 13h
2: mov CX,2909h ; Track 29h sector 09h
3: xor DX,DX ; Drive 0, head 0
4: int 13h ; Read sector
5: jnc Bad ; If no error then it's a copy
6: cmp AH,10h ; Was it a CRC error
7: jne Bad ; No, then it's a copy
8: mov AX,0h ; clear error flag
9: jmp Done ; we are done
Bad: mov AX,1 ; set error flag
Done: ret ; we are done
What is the above code trying to do. Well, it's checking for a KEY on
track 29h. That key is sector 09h. Normally sector 09h would not have an
error. On a read to the original disk, after the int13 (line 4) is executed,
the carry flag (CF) would be set. The jnc in line 5 would jump if CF is not
set (indicating no error, which is bad since the original disk would have an
error there). The next line checks AH to see if it is 10h. This is checking
to see if the error was a Bad CRC on the read (the error that should be
there). If it was not, then again it is not the protected disk. Only after
both of thoses conditions are met, will the protection routine return a
"GOOD" result.
The key here is the value returned in AX an possibly CF. When the disk is
the original, AX would return the value of 0000h and CF = 1 but when it was a
copy, it would return 0001h and CF = 0 or 1. Since on a bad return, CF can be
0 or 1 then it is preaty safe to assume CF is not used to signal the return.
So what must we do to beat the protection routine, well, simply return from
this CHECK with AX = 0000h. Simple. Just change line 1 to "mov AX,0000h" and
line 2 to "RET". This will just bypass the check.
Now, this example is quite simple and would probally never be used in a
REAL protection routine. I kept it simple to show the point, see the example
on how to crack DRAWING ASSISTANT for a better example.
The second and more perferd method is to simply bypass the call to the
protection routine and kill of the section of code that test for the check
position. Take the following example:
10: call 1 ; call the first example
11: cmp AX,0 ; Was it the original
12: jz Good2 ; Yes, then good
13: ... BAD it was a copy ; No, then bad
Good2:
The above example, when used with the last example show a typical call to
a protection routine. The perfered method to crack this protection would not
be to simply fake the return, but to remove the call to the protection. How
to do it, simple. Just jump over the check. Change line 10 to "jmp Good2".
This will bypass the protection routine.
Now, you might ask why would you want to take the extra step of finding
the call to the protection routine rather than simply faking an int13 and
returning with the proper registers set. 2 reasons. First, What if there
wasn't enough room to setup the registers the way you needed them. Then you
would have to take the extra step. Second, what if somewhere down the line,
that routine is used for something else (like the int13 is modified into an
int10 in a game). Since you have changed the bytes at that location, the
modifying routine would create code that wasn't exepcted. But as always, if
you can fake the return, and the program works, leave it. After all, not to
many people go around look at other peoples cracks (do they???).
Now, what to do, if the program actually reads in important data from the
disk. Well, there are 2 ways to go about this (possibly more). First, you
could patch the program so that when it calls it's protection routine, it
jumps to your user routine that opens a file and reads in the data to the
right place. This method is preaty simple to add to a .COM file but a much
harder to patch on to the back of a .EXE. I won't really go in to this method
much more than to say use your brains. It's not a difficult concept.
The other method, is to create a LOADER or a TSR. I suggest creating an
Interrupt Service Routine (ISR) that handles loading in the data. For
example, let say you wrote a routine to read in the needed data for a file.
It is not to difficult to convert that routine into an ISR. (For notes on ISR
and TSRs, try reading The Waite Group's "MS-DOS PAPERS". It has one of the
best sections on the subject).
Consider this following example:
A: call 1 ; test protection
B: jnc Good ; was it successfull
C: ... BAD load ; no then it's a copy
... EXIT TO DOS ; so exit to dos
Good: ... Good load ; yes then it original
call 7C00:0000 ; then jump of protection
; data
1: mov ax,0209 ; Read 9 sectors starting from
2: mov cx,290a ; Track 29h Sector 0Ah (10)
3: xor dx,dx ; for drive A: head 0
4: mov bx,7c00 ; read to 7c00:0
5: mov es,bx ;
6: mov bx,0 ;
7: int 13h ;
8: ret
What the above example dos. Lines 1-8 try to read in sectors 0Ah -12h for
track 29h on drive A:. This is the protection check routine. Lines A -Good
attempt to check the protection, and then if the check is good (CF = 0) then
a call to the loaded in code (the data loaded in by the protection check) is
made.
What we want to do, is somehow when INT 13h is called, load in the needed
data for disk. Well, here is my suggestion. First, I would change line 7 from
"int 13h" to "int BBh". Next, I would create a small .COM loader that would
execute the main program as a child process (read the DOS TECH REF on the
EXEC function). But before I did that, I would write an ISR (interrupt
service routine) for INT BBh. Here is the general outline for the ISR
■ Use dos to open the file containing the needed data
■ Read in the data to ES:BX (where int 13h would put it)
■ Close the file ■ set AX to 0000 and clear CF
■ iret
The loader would go like this :
■ Get current int BBh address (DOS func. 35h)
■ Set int BBh address to ours (DOS func. 25h)
■ use DOS to EXECUTE (Dos func. 4Bh) the program to be cracked
■ Restore the address of BBh
Well, that about all I have to say about cracking a dos file. I hope this
section has been usefull to you. Next I will show by example the techinques
in this section while cracking I.B.M. Drawing Assistance (1.00).
One last thing. After you have cracked the program, try running it from a
hard drive with PW set to trap calls to INT 21h function 1Bh (get fat byte).
If the program make a call to here, get the address and find that section of
code. What the program is trying to do is check to see if you are running
from a hard drive (most programs have diffrent protection routines for hard
drives). When you find it, simply replace the "INT 21h" with a "MOV
DS:[BX],FDh". This will fake the program in to thinking you are working on a
floppy disk.
Ok, for our example we will be removing the code from IBM's Drawing
assistant. Now now, I know it's not the best program out there, but shit,
It's hard to find shit with on disk copy protection anymore. So here we go...
I needed 3 programs in cracking the assist. series. Locksmith by Alph
Logic, Periscope debugger, and DEBUG (supplied with DOS). By using these
three programs together, I was able to figure out and remove the copy
protection in under 30 minutes.
Drawing Assistant (DA) is IBM's answer to colorpaint for the Jr. It is a
simple drawing program (a more advanced version is included in StoryBoard
Deluxe) but easy to learn and use. So far, I have only seen version 1.00 of
this program.
DA made calls to the copy protection routine in 3 diffrent modules. The
files "SETDRAW.EXE", "DRAWASST.EXE" and "DRAWASST.TWO" all contained calls to
the copy protection. Also, "DRAWASST.TWO" and "DRAWASST.EXE" are for all
intensive puporses then same file.
I first started off by loading DRAWASST.EXE with debug and searched for
any int 13's by executing the debug command
s CS:0 FFFF CD 13 Search CS:0 - CS:FFFF for CD 13 (int 13)
I located 2 diffrent calls to int 13h, so I then listed them. Here is
what I found...
{ First, some initialization routines }
18FD:0343 1E PUSH DS
18FD:0344 B80000 MOV AX,0000
18FD:0347 50 PUSH AX
18FD:0348 B89724 MOV AX,2497
18FD:034B 8ED8 MOV DS,AX
18FD:034D BB1000 MOV BX,0010
18FD:0350 2E CS:
18FD:0351 8A07 MOV AL,[BX]
18FD:0353 3C00 CMP AL,00
18FD:0355 7418 JZ 036F
{ This set is called if DA has been installed on the hard drive }
{ When cracked, this will NEVER be called }
18FD:0357 B419 MOV AH,19
18FD:0359 CD21 INT 21
18FD:035B 8AD0 MOV DL,AL
18FD:035D FEC2 INC DL
18FD:035F B41C MOV AH,1C
18FD:0361 CD21 INT 21
18FD:0363 8A07 MOV AL,[BX]
18FD:0365 BB9724 MOV BX,2497
18FD:0368 8EDB MOV DS,BX
18FD:036A 3CF8 CMP AL,F8
18FD:036C 7475 JZ 03E3
18FD:036E CB RETF
{ This set is called if DA is running from the floppy }
18FD:036F B419 MOV AH,19
18FD:0371 CD21 INT 21
18FD:0373 FEC0 INC AL
18FD:0375 B400 MOV AH,00
18FD:0377 A320C6 MOV [C620],AX
18FD:037A 8AD0 MOV DL,AL
18FD:037C B41C MOV AH,1C
18FD:037E CD21 INT 21
18FD:0380 8A07 MOV AL,[BX]
18FD:0382 BB9724 MOV BX,2497
18FD:0385 8EDB MOV DS,BX
18FD:0387 3CF8 CMP AL,F8
18FD:0389 7408 JZ 0393
{ Here is the called to read in the key disk }
18FD:038B E8A675 CALL 7934
18FD:038E 3D0100 CMP AX,0001
18FD:0391 7450 JZ 03E3
Let's take these code segments 1 at a time. The fist, is some simple
initialization routines. Here is the code, only this time full comments are
added.
{ First, some initialization routines }
; Setup for return to DOS
18FD:0343 1E PUSH DS
18FD:0344 B80000 MOV AX,0000
18FD:0347 50 PUSH AX
; Setup DS to point to the data segment
18FD:0348 B89724 MOV AX,2497
18FD:034B 8ED8 MOV DS,AX
18FD:034D BB1000 MOV BX,0010 ; CS:10 points to
; installed flag
18FD:0350 2E CS:
18FD:0351 8A07 MOV AL,[BX]
18FD:0353 3C00 CMP AL,00 ; If not installed, jump to
; diskette
18FD:0355 7418 JZ 036F ; routines
What we are want to do, is fool DA in to thinking that it is stilling
loading from diskette. Nothing really needs to be changed in this segment,
but, just to be safe, we will force the jump at 355. To change the current
values, use DEBUG's [A]ssembler command.
A CS:355
18FD:355 JMP 36F
Now, we have forced the jump, we can move on to the third code segment
skipping over the second since it will never be called again. The 3rd code
segment checks to see if you are using a hard drive. It does so by first
getting the logical drive letter, then reading in the FAT descriptor byte for
that drive. Here is the commented code.
{ This set is called if DA is running from the floppy }
; First, get the current drive
18FD:036F B419 MOV AH,19 ; DOS function 19h -; Get
; Current Drive
18FD:0371 CD21 INT 21
18FD:0373 FEC0 INC AL ; Add 1 for BIOS
18FD:0375 B400 MOV AH,00 ; Clear AH
18FD:0377 A320C6 MOV [C620],AX ; Store it at C620
18FD:037A 8AD0 MOV DL,AL ; Store it in DL
18FD:037C B41C MOV AH,1C ; DOS function 1Ch
; Get Fat desc.
18FD:037E CD21 INT 21 ; returns pointer
; in DS:BX
18FD:0380 8A07 MOV AL,[BX] ; Get the actual
; byte
18FD:0382 BB9724 MOV BX,2497 ; Restore DS
18FD:0385 8EDB MOV DS,BX
18FD:0387 3CF8 CMP AL,F8 ; Check to see if
; it is a H/D
18FD:0389 7408 JZ 0393 ; Yes, then jump abort
{ Fall in to the check for the key disk }
As you can see, this section of code is quite straigth forward. It just
checks to see if you are using a hard drive. What we want to do is to fake an
DOS function 1Ch and return the value for a floppy. This is done by putting
the value of FDh in AL then NOPing the rest. Again use the Debug's [A]
command.
A CS:37C
18FD:037C MOV AL,FD
18FD:0380 NOP
18FD:0381 NOP
18FD:0382 NOP
18FD:0383 NOP
Now, you might ask why I didn't simple force a jump over the code. The
answer is what if DA uses the value at C620 at a later time (which it doesn't
but let's pretend). If I had forced the jump then the value might not have
been initialized and the crack might not work. Now that we have simulated
running from diskette, we must deal for the check for the key disk.
This is where Periscope came in to play. Using periscope, I made the
above corrections and ran the program up till CS:038B (the call to the
check). Here is the code, including the actual check. I have indented the
check to make it easier to read.
{ Here is the called to read in the key disk }
18FD:038B E8A675 CALL 7934 ; Check key on disk
; (track 27h side 0)
18FD:7934 A120C6 MOV AX,[C620] ; Get drive letter
18FD:7937 FEC8 DEC AL
18FD:7939 A23BC6 MOV [C63B],AL ; Store it for later
18FD:793C 1E PUSH DS
18FD:793D 07 POP ES ; Setup pointers to what sectors
; to try to read
18FD:793E BB30C6 MOV BX,C630
18FD:7941 891E39C6 MOV [C639],BX
18FD:7945 C6063CC603 MOV BYTE PTR [C63C],03
18FD:794A C6063DC601 MOV BYTE PTR [C63D],01
; Reset the disk
18FD:794F B400 MOV AH,00
18FD:7951 CD13 INT 13
; Get address of sector to read an put it in CL
18FD:7953 8B1E39C6 MOV BX,[C639]
18FD:7957 8A0F MOV CL,[BX]
; Setup the rest of the read information
18FD:7959 BBAE3D MOV BX,3DAE
18FD:795C 81C3D007 ADD BX,07D0
18FD:7960 B001 MOV AL,01
18FD:7962 B527 MOV CH,27
18FD:7964 8A163BC6 MOV DL,[C63B]
18FD:7968 B600 MOV DH,00
18FD:796A B402 MOV AH,02
18FD:796C CD13 INT 13
; Test for an error and jump if none is present (ie: the copy protection
has been removed)
18FD:796E 80FC00 CMP AH,00
18FD:7971 740C JZ 797F
; test the bad read (protection is missing) 3 times
18FD:7973 FE0E3CC6 DEC BYTE PTR [C63C]
18FD:7977 75D6 JNZ 794F
18FD:7979 B80000 MOV AX,0000
18FD:797C EB13 JMP 7991
; Get next sector to check. If finished, set the flag and ; return.
18FD:797F FF0639C6 INC WORD PTR [C639]
18FD:7983 FE063DC6 INC BYTE PTR [C63D]
18FD:7987 803E3DC603 CMP BYTE PTR [C63D],03
18FD:798C 75C1 JNZ 794F
18FD:798E B80100 MOV AX,0001
18FD:7991 C3 RET
; Check to see if the OK flag was set (ax = 0001h means check was good)
18FD:038E 3D0100 CMP AX,0001
18FD:0391 7450 JZ 03E3
The key check used in DA is quite simple. It simple tries to read in the
illegaly numbered sectors on Track 27h side 0h. If they are missing, it
assumes that it is running a pirated copy. What we must do, is to fool the
scheme in to thinking a good read happened. I choses to fake the read using
the easiest method. Since the protection scheme only check to see if AX
returns the value > 0000h, I simply modified the routine at 1BFD:7934 to set
AX to 0000h and then return. Here is the new code (enter using debug's A
command)...
A 1BFD:7934
1BFD:7934 MOV AX,0000
1BFD:7936 RET
Now, this file is unprotected and if you type "G" at debug's command
prompt, the program will execute, sort-of. See DRAWASST.EXE calls
DRAWASST.TWO which also has the protection scheme. So both must be changed.
To make to changes perement in DRAWASST.EXE, rename the file to DRAWASST.DEB
and edit it. To find the address of the start of the protection code, use
debug's search command...
S CS:0 FFFF B4 19 CD 21 8A D0
Now, just uses the modified address to change the program (the code will
still be the same, just all calls and jumps will be to diffrent addresses).
Use the same process to stip DRAWASST.TWO (it uses the exact same code).
When you have both of those files unprotected, you can move on to
unprotecting the setup program "SETDRAW.EXE"
DRAWASST.EXE AND .TWO are not the only programs that make calls to the
protection routine. SETDRAW.EXE also makes the above calls. Although the
check here is much easier to bypass. Here is the asm listing of SETDRAW with
all of the calls to the protection. This time, I will not go in to quite as
much detail as I did for the other two version.
I will tell you this. When SETDRAW checks the key disk, first it checks
to see if the protection exists and then to see if the track hasn't been
modified. It again uses AX to determine what happeded. I used Periscope to
trace through the original version to find out what the correct values are.
Here is the asm code...
; Initialization - checks the current mode and saves it.
18FD:0000 1E PUSH DS
18FD:0001 B80000 MOV AX,0000
18FD:0004 50 PUSH AX
18FD:0005 B8321A MOV AX,1A32
18FD:0008 8ED8 MOV DS,AX
18FD:000A B40F MOV AH,0F
18FD:000C CD10 INT 10
18FD:000E 3C02 CMP AL,02
18FD:0010 740D JZ 001F
18FD:0012 3C03 CMP AL,03
18FD:0014 7409 JZ 001F
18FD:0016 A28900 MOV [0089],AL
18FD:0019 B002 MOV AL,02
18FD:001B B400 MOV AH,00
18FD:001D CD10 INT 10
; Gets the current drive
18FD:001F B400 MOV AH,00
18FD:0021 B419 MOV AH,19
18FD:0023 CD21 INT 21
18FD:0025 A28700 MOV [0087],AL
18FD:0028 8AD0 MOV DL,AL
18FD:002A FEC2 INC DL
; Checks the FAT descriptor
18FD:002C B41C MOV AH,1C
18FD:002E CD21 INT 21
18FD:0030 8A07 MOV AL,[BX]
18FD:0032 BB321A MOV BX,1A32
18FD:0035 8EDB MOV DS,BX
18FD:0037 C606880000 MOV BYTE PTR [0088],00
18FD:003C 3CF8 CMP AL,F8
18FD:003E 742A JZ 006A
; Read in protection scheme
18FD:0040 8A168700 MOV DL,[0087]
18FD:0044 E87E0A CALL 0AC5
18FD:0047 C606880000 MOV BYTE PTR [0088],00
18FD:004C 3D0000 CMP AX,0000
18FD:004F 7419 JZ 006A
; Read in the dummy scheme
18FD:0051 C606880001 MOV BYTE PTR [0088],01
18FD:0056 8A168700 MOV DL,[0087]
18FD:005A B84500 MOV AX,0045
18FD:005D E8BD0A CALL 0B1D
18FD:0060 3D0000 CMP AX,0000
18FD:0063 7405 JZ 006A
; Start of actual routine.
18FD:0065 C606880000 MOV BYTE PTR [0088],00
There is isn't much to say about the above code. To bypass it, we will
change the hard drive check (int 21 function 1c). Do the same thing we did
for DRAWASST.EXE
A 18FD:2C
18FD:002C mov AL,FD
18FD:002E nop
18FD:002F nop
18FD:0030 nop
18FD:0031 nop
Now, just jump over the check to the key disk.
A 18FD:40
18FD:0040 jmp 0065
And thats it. Now SETDRAW is unprotected. Drawing Assistant may be used,
copied or backed up at your pleasure.
As you can see, this was a good example although the fact that if you
only made the changes in DRAWASST.EXE and not in DRAWASST.TWO then the
program would copy DRAWASST.TWO to DRAWASST.EXE to restore the protection was
a bit strange.
Well, I hope you are proud. But be warned, next we take on DOC checks, so
get a good nights sleep. Till then, play lots of SMASH T.V.
-Buckaroo
-Banzai